{"id":477,"date":"2017-03-15T11:53:42","date_gmt":"2017-03-15T10:53:42","guid":{"rendered":"http:\/\/userpage.fu-berlin.de\/~eigler\/?page_id=477"},"modified":"2024-07-31T13:21:35","modified_gmt":"2024-07-31T11:21:35","slug":"technical-equippement","status":"publish","type":"page","link":"https:\/\/userpage.fu-berlin.de\/~eigler\/technical-equippement\/","title":{"rendered":"Lab"},"content":{"rendered":"\n<div class=\"wp-block-group alignwide is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group__inner-container\">\n<p class=\"has-text-align-center\">Our equipment can be booked <em>via<\/em> <a href=\"https:\/\/fub.openiris.io\/landing\/?ReturnUrl=%2f\">Open IRIS<\/a>.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:46% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"697\" src=\"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2024\/07\/Zentrifuge-1024x697.jpg\" alt=\"\" class=\"wp-image-3685 size-full\" srcset=\"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2024\/07\/Zentrifuge-1024x697.jpg 1024w, https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2024\/07\/Zentrifuge-300x204.jpg 300w, https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2024\/07\/Zentrifuge-768x523.jpg 768w, https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2024\/07\/Zentrifuge.jpg 1160w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading\"><p><strong>Centrifuge<\/strong><\/p> <\/h4>\n\n\n\n<p class=\"has-normal-font-size\"><p>Tabletop centrifuge <em><strong>Sigma 4-16KS<\/strong><\/em> equipped with large fixed-angle rotors to purify\u00a0particle dispersions up to volumes of 3 liters at high RCF values.\u00a0For smaller volumes, we additionally use\u00a0a micro centritrifuge WiseSpin CF-10.<\/p><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile is-vertically-aligned-center\" style=\"grid-template-columns:auto 30%\"><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading alignwide\"><p><strong>Tip Sonicator<\/strong><\/p><\/h4>\n\n\n\n<p><p>For the delamination of chemical processed graphites and the production of single-layered carbon materials with defined particle sizes we use the tip-sonicator <em><strong>Sonopuls UW3200<\/strong><\/em>\u00a0from Bandelin.<\/p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"1024\" src=\"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2024\/07\/Bild-1-1-576x1024.jpg\" alt=\"\" class=\"wp-image-3686 size-full\" srcset=\"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2024\/07\/Bild-1-1-576x1024.jpg 576w, https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2024\/07\/Bild-1-1-169x300.jpg 169w, https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2024\/07\/Bild-1-1.jpg 605w\" sizes=\"(max-width: 576px) 100vw, 576px\" \/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:28% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"571\" height=\"1000\" src=\"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2017\/03\/microscope.jpg\" alt=\"\" class=\"wp-image-582 size-full\" srcset=\"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2017\/03\/microscope.jpg 571w, https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2017\/03\/microscope-171x300.jpg 171w\" sizes=\"(max-width: 571px) 100vw, 571px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading\"><p><strong>Microscope<\/strong><\/p><\/h4>\n\n\n\n<p>Our laboratory is equipped with a &nbsp;<strong><em>Nikon Eclipse LV150-NL<\/em><\/strong> Light microscope. A LED light source in combination with 20x\/50x\/100x plan objectives and 3 MP camera. The&nbsp;microscope is&nbsp;the perfect tool for analyzing particle sizes and distributions.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 37%\"><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading\"><p><strong>Langmuir-Blodgett Through<\/strong><\/p><\/h4>\n\n\n\n<p><p>For the preparation of closed, single layered films of graphene and its functionalized derivatives on 300 nm SiO<sub>2<\/sub>\/Si wafer we use a <em><strong>Kibron \u00b5Throug<\/strong><\/em> system.<\/p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"673\" height=\"533\" src=\"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2017\/03\/LB.jpg\" alt=\"\" class=\"wp-image-583 size-full\" srcset=\"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2017\/03\/LB.jpg 673w, https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2017\/03\/LB-300x238.jpg 300w\" sizes=\"(max-width: 673px) 100vw, 673px\" \/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:28% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"673\" height=\"897\" src=\"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2017\/03\/Lyo.jpg\" alt=\"\" class=\"wp-image-584 size-full\" srcset=\"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2017\/03\/Lyo.jpg 673w, https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2017\/03\/Lyo-225x300.jpg 225w\" sizes=\"(max-width: 673px) 100vw, 673px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading\"><p><strong>Lyophilisation<\/strong><\/p><\/h4>\n\n\n\n<p><p>For drying aqueous dispersions of carbon nanomaterials\u00a0we use a<em><strong> Christ Alpha 1-2LDplus<\/strong><\/em>.<\/p><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading\"><strong>Atomic Force Microscope<\/strong><\/h4>\n\n\n\n<p><em><strong>JPK NanoWizzard Ultra equipped with:<\/strong><\/em><\/p>\n\n\n\n<p>30 \u00b5m x 30 \u00b5m scanner; x,y-motorized stage,&nbsp;TopView Optic, Kelvin Probe and Conductive AFM module. AC mode and QI advanced mode are available.<\/p>\n\n\n\n<p>The AFM from JPK is a top-scanner controlled by a linux workstation. The cantilever is mounted onto a glass block with an optical access from the top. With this setup it is possible to measure in liquids (water) as well as in air. Either tapping mode oder quantitative analysis mode is available. The latter works with measuring force-distance curves and makes the analysis of mechanical properties possible. The automated table allows using scripts to plan experiments and make statistical analysis from different places. More specialized are the electrical modes, which require other tips or modules. Determination of work function or electrical inhomogeneities of suitable samples is possible.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"454\" height=\"269\" src=\"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2017\/03\/AFM.png\" alt=\"\" class=\"wp-image-529 size-full\" srcset=\"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2017\/03\/AFM.png 454w, https:\/\/userpage.fu-berlin.de\/~eigler\/wp-content\/uploads\/2017\/03\/AFM-300x178.png 300w\" sizes=\"(max-width: 454px) 100vw, 454px\" \/><\/figure><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Our equipment can be booked via Open IRIS. Centrifuge Tabletop centrifuge Sigma 4-16KS equipped with large fixed-angle rotors to purify\u00a0particle dispersions up to volumes of 3 liters at high RCF values.\u00a0For smaller volumes, we additionally use\u00a0a micro centritrifuge WiseSpin CF-10. Tip Sonicator For the delamination of chemical processed graphites and the production of single-layered carbon [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":3,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"_links":{"self":[{"href":"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-json\/wp\/v2\/pages\/477"}],"collection":[{"href":"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-json\/wp\/v2\/comments?post=477"}],"version-history":[{"count":25,"href":"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-json\/wp\/v2\/pages\/477\/revisions"}],"predecessor-version":[{"id":3699,"href":"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-json\/wp\/v2\/pages\/477\/revisions\/3699"}],"wp:attachment":[{"href":"https:\/\/userpage.fu-berlin.de\/~eigler\/wp-json\/wp\/v2\/media?parent=477"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}